MITSUBISHI INVERTER, 0.2KW, 220V, (FR-D720-0.2K)
Altitude / vibration : Sea level 1000 m or less · 5.9 m / s 2 or less
- Estimated Lead Time : 7-10 Working Days
- Manufacturer : Mitsubishi Electric
- FR-D720-0.2K-CHT
- Product series : FREQROL-D 700
- Type : Easy · Small inverters FREQROL-D 700 series Three-phase 200V
- Product model name : FR-D720-0.2K
- Applicable motor capacity (kW) : 0.2 kW
- output Rated capacity (kVA) : 0.6
- Rated current (A) : 1.4
- Overload current rating : 150% 60 s, 200% 0.5 s (at inverse time characteristic)
- Voltage : 3 phase 200~240V
- Regenerative braking torque : Maximum value · Allowable usage rate : –
- Power supply Voltage class : Three-phase 200V class
- Rated input AC voltage · Frequency : 3 phase 200 ~ 240 V 50 Hz / 60 Hz
- AC voltage allowable variation : 170 to 264 V 50 Hz / 60 Hz
- Frequency tolerance variation : ± 5%
- Power supply equipment capacity (kVA) : 0.7
- Protective structure (JEM 1030) : Closed type (IP 20), fully closed structure series is IP 40.
- cooling method : Self-cooling
- Approximate mass (kg) : 0.5
- Control specification control method : Soft-PWM control / high carrier frequency PWM control (V / F control, general magnetic flux vector control, optimum excitation control can be selected)
- Output frequency range : 0.2 to 400 Hz
- Frequency setting resolution : Analog input : 0.06 Hz / 60 Hz (Terminal 4: 0 to 20 mA / 10 bits), 0.06 Hz / 60 Hz (Terminals 2, 4: 0 to 10 V / 10 bits), 0.12 Hz / 60 Hz (Terminals 2 and 4: 0 to 5 V /
- Digital input : 0.01 Hz
- Frequency accuracy : Analog input : Within ± 1% of maximum output frequency (25 °C ± 10 °C)
- Digital input : Within 0.01% of setting output frequency
- Voltage / frequency characteristics : Base frequency 0 to 400 Hz Optional setting, constant torque · reduction Torque pattern selectable
- Starting torque : 150% or more (at 1 Hz) When slip correction is set by general-purpose magnetic flux vector control
- Torque boost : Manual torque boost
- Acceleration / deceleration time setting : 0.1 ~ 3600 s (Individual acceleration / deceleration setting possible), linear or S-shaped acceleration / deceleration mode selectable
- DC braking : Operating frequency (0 to 120 Hz), operating time (0 to 10 s), operating voltage (0 to 30%) variable
- Stall prevention operation level : Operating current level selectable (0 to 200% variable), selectable
- Torque limit level : None
- Operating specification Driving function : Upper / lower limit frequency setting, frequency jump operation, external thermal input selection, instantaneous power failure restart operation, forward / reverse rotation prevention, remote setting, second function, multi-speed operation, regeneration avoidance, slip correction, operation mode selection, offline auto tuning Function, PID control, Computer link operation (RS – 485), Optimum excitation control, Power outage stop, Speed ??smoothing control, Modbus – RTU
- Frequency setting signal : Number of analog input terminals : 2 points
- Analog input terminal specification : Terminal 2: 0 to 10 V, 0 to 5 V selectable, terminal 4: 0 to 10 V, 0 to 5 V, 4 to 20 mA selectable
- Digital input : Input by operation panel, parameter unit, frequency setting unit selectable
- Start signal : Individual normal rotation / reverse rotation, start signal self-holding input (3 wire input) selectable
- input signal : Number of terminal points (contact input) : 5 points
- Pulse train input : None
- Input terminal selectable signal : External thermal input, PU – external operation switching, V / F switching, output stop, start self-holding selection, positive terminal selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control valid terminal Pr. 178 to Pr. 182 (input terminal function selection) arbitrary signal from the external interlock of the PU operation, PU operation, PU operation, changeover command, inverter reset, PUNET operation changeover, external-NET operation changeover, Select by
- Output signal : Output terminal (open collector output) Number of points : 1point
- Number of output terminals (relay output) : 1point
- Output terminal selectable signal : During inverter operation, frequency reached, overload alarm, output frequency detection, regenerative brake pre alarm, electronic thermal pre alarm, inverter operation ready, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation Safety monitor output, Safety monitor output 2, Retrying, Lifetime alarm, Current average value monitor, Remote output, Minor fault output , Abnormal output, abnormal output 3, maintenance timer alarm, selected by Pr. 190, Pr. 192, Pr. 197 (output terminal function selection).
- Output terminal selectable signal (when option is installed) : Can not install built-in option
- Number of display terminal output terminals : 1point
- Display meter output terminal specification : FM: Up to 2.4 kHz
- Pulse train output : None
- Display meter output terminal selectable signal : Output frequency, Output current (steady state), Output voltage, Frequency setting value, Converter output voltage, Regenerative brake usage rate, Electronic thermal load factor, Output current peak value, Converter output voltage peak value, Reference voltage output, Motor load factor, PID Pulse train output (1440 pulses / s / full scale) is selected by Pr.54 FM terminal function selection, target value, PID measured value, output power, PID deviation, motor thermal load factor,
- display control panel : Operating condition : Output frequency, Output current (steady state), Output voltage, Frequency set value, Integrated energization time, Actual operating time, Converter output voltage, Regenerative brake usage rate, Electronic thermal load factor, Output current peak value, Converter output voltage peak value, Motor Selectable from load factor, PID target value, PID measurement value, PID deviation, inverter input / output terminal monitor, output power, integrated power, motor thermal load factor, inverter thermal load factor, PTC thermistor resistance value
- Abnormal content : Abnormality content is displayed during operation of protection function, 8 times of abnormality content is memorized (output voltage, current, frequency, total energization time immediately before protection function operation)
- Protection / alarm function : Overcurrent during acceleration, overcurrent during deceleration, overcurrent during deceleration, overvoltage during acceleration, overvoltage during constant speed, deceleration Overvoltage, inverter protection thermal operation, motor protection thermal operation, fin overheating, At startup Output side ground fault current, output phase loss, external thermal operation, PTC thermistor operation, parameter error, PU missing occurrence, over retry count, CPU abnormality, brake transistor abnormality, inrush resistance overheat, analog input abnormality, stop due to stall prevention , Overcurrent stall prevention, Over-voltage stall prevention, PU stop, Parameter write error, Regenerative brake pre-alarm, Electronic thermal pre-alarm, Maintenance output, Undervoltage, Operation Panel lock, Password setting, Inverter resetting, Safety Stopped
- environment Ambient temperature : -10 °C to + 50 °C (no freezing) (-10 °C to + 40 °C when fully closed structure specifications)
- Ambient humidity : 90% RH or less (no condensation)
- storage temperature : -20 °C to + 65 °C
- atmosphere : Indoor (no corrosive gas, flammable gas, oil mist, dust)
- General-purpose three-phase 200V class Applicable motor capacity 0.2KW
- Mitsubishi inverter’s new standard pring clamp terminal (control circuit) realized high reliability and easy wiring. Equipped with a safety stop function, it is possible to cut emergency output with high reliability with a blocking circuit by hardware.
- Equipped with the best-in-class performance in the compact body General-purpose magnetic flux vector control is installed in the compact body (3.7 K or less) of the same mounting size as our FREQROL-S500 series which is the smallest inverter of the company, and 150% (3.7 K or less) High torque has been realized.
- Fulfilling functions Suitable for fan and pump applications Excitation control · PID control, deceleration stop function at power outage for machine tool applications, general purpose magnetic flux vector control for food applications · brake resistor connection (0.4 K to 15 K) and other applications Various functions were carried.
- Weight : 1.5 Kg
Reviews